Linear accelerator Elekta Evo

 

Elekta Evo is a next-generation CT-Linac designed for high-precision external beam radiation therapy (EBRT) for patients across various oncological indications. The system offers exceptional clinical versatility — ranging from conventional radiotherapy to stereotactic radiosurgery (SRS) — and supports both online and offline adaptive radiation therapy workflows.

Evo is equipped with Iris, a new high-precision imaging system featuring an AI-enhanced imaging suite. This system expands the capabilities of IGRT (Image-Guided Radiation Therapy) and adaptive treatment, ensuring a personalized approach for every patient during every session.

Clinical Capabilities and Workflow Optimization

Evo supports a wide range of EBRT techniques and enables the implementation of new clinical approaches tailored to patient needs and departmental workflows:

  • Flexible switching between IGRT modes, as well as online and offline workflows.
  • A universal platform for current treatment regimens — from conventional to stereotactic.
  • An integrated digital control system optimized for dynamic delivery techniques.
  • Increased confidence in dose delivery, enhanced patient safety, and optimized patient throughput.
  • HexaPOD Evo RT System for robotic positioning with sub-millimeter accuracy, essential for SRS/SBRT.

Iris: High-Precision AI-Enhanced Imaging

Evo includes Iris, a high-precision AI-enhanced imaging solution for IGRT and adaptive protocols:

  • CBCT imaging enhanced by the Polyquant CT algorithm, incorporating AI-driven scatter correction and iterative image reconstruction (GPU-accelerated).
  • Anatomy-specific AI scatter models to increase accuracy and reduce noise.
  • Utilization of Polyquant CT to determine material mass density and electron density for treatment planning.
  • Improved HU (Hounsfield Units) measurements for more accurate quantitative image assessment.
  • Significantly enhanced contrast for visualizing target boundaries and adjacent healthy tissues.

High-Precision Stereotactic Therapy with Dynamic Modulation

Evo integrates with Elekta ONE® | Planning to provide high-resolution modulation for faster and more accurate stereotactic procedures:

  • Elekta IntelliBeam for intelligent high-speed treatment with flexible control point management and single-arc delivery capabilities.
  • Treatment of multiple small SRS targets with a 1 mm virtual leaf width.
  • A large 40 × 40 cm radiation field, allowing coverage of multiple targets while minimizing the need for multiple isocenters or arcs.
  • High-speed MLC (up to 6.5 cm/s) with low leakage, combined with dynamic Y-jaws (up to 9 cm/s) and High Dose Rate Mode (6 FFF: 1400 MU/min; 10 FFF: 2200 MU/min) — enabling SRS/SBRT execution within a standard time slot.

End-to-End Quality Assurance (QA)

Elekta ONE | QA provides a centralized and comprehensive quality control suite for the equipment, automating and simplifying system performance checks:

  • QA validation using the Monte Carlo dose optimization reference algorithm in Elekta ONE | Planning.
  • EPID dosimetry in Elekta ONE | QA for patient-specific QA and in-vivo dosimetry.
  • Elekta ONE | QA powered by ThinkQA: a 3D collapsed cone convolution algorithm for secondary dose verification in IGRT and adaptive workflows.
  • Optional Integral Quality Monitor (IQM) for stereotactic QA and real-time verification.

High-Precision Positioning and Treatment Safety

Elekta Evo includes the HexaPOD Evo RT System, a robotic positioning system with 6 degrees of freedom (6DoF) that ensures sub-millimeter accuracy in patient positioning. This level of precision is critical for delivering high-dose fractions in stereotactic protocols, where reproducibility and dose delivery stability requirements are most stringent. The system is also designed to enhance clinical processes and potentially increase departmental capacity.

Download PDF Brochure Download PDF Brochure